Command with Address Specification
LX900 RS232 Codes-Expanded Technical Reference Information 8-1
020-000034-01 Rev 1. (03/08)
7 Error Codes Table
Error
Code
Contents
? -When the received data cannot be decoded:
-Parameter designation error (wrong digit number, including invalid value, etc.)
000 Normal reception (This is “Not” error)
101 Specified function is not available in the selected mode
102 Specified value is out of range (Not reflected)
103 Command mismatched to Hardware (the command is for Optional function, which is not
implemented)
201 Incremented or decremented value or values are beyond upper or lower limits.
301 Not executable due to screen capturing in process. Prompting reissue of the command after a
while.
302 Not executable due to Auto set up in operation. Prompting reissue of the command after a while.
303 Not executable due to memory card viewer in process. Prompting reissue of the command after
a while.
402 Not executable due to PIN code in operation. Prompting reissue of the command after a while.