Command with Address Specification
LX900 RS232 Codes-Expanded Technical Reference Information 8-15
020-000034-01 Rev 1. (03/08)
9.7.9 CR_NMSLOT1 Command
Command “CR_NMSLOT1” [CR]
Detail Get the board name inserted to Slot1
Acceptable “000_%1” [CR]
%1
“HDCP-DVI2” - Input1/ New HDCP&DVI board
“5BNC-VIDEO”- Input2/ New Video board
“VGA” - VGA D-Sub board
“5BNC” - Component board
“DUAL-SDI” - HD&SD-SDI board
“HDCP-DVI” - HDCP&DVI board
“WARP” - Warp board
“NOTERMINAL” - There is no board inserted
Response
Unacceptable “?” [CR]
9.7.10 CR_NMSLOT2 Command
Command “CR_NMSLOT2” [CR]
Detail Get the board name inserted to Slot 2
Acceptable “000_%1” [CR]
%1 The same data as CF_NMSLOT1
Response
Unacceptable “?” [CR]
9.7.11 CR_NMSLOT3 Command
Command “CR_NMSLOT3” [CR]
Detail Get the board name inserted to Slot 3
Acceptable “000_%1” [CR]
%1 The same data as CF_NMSLOT1
Response
Unacceptable “?” [CR]
9.7.12 CR_NMSLOT4 Command
Command “CR_NMSLOT4” [CR]
Detail Get the board name inserted to Slot 4
Acceptable “000_%1” [CR]
%1 The same data as CF_NMSLOT1
Response
Unacceptable “?” [CR]