Command with Address Specification
LX900 RS232 Codes-Expanded Technical Reference Information 8-27
020-000034-01 Rev 1. (03/08)
8.9.14 CF_FILCTL Command
Command “CF_FILCTL_%1” [CR]
%1 “ROLL” - Execute operation of scroll of filter
Detail Execute operation of scroll of filter
Acceptable Acceptable
Response
Unacceptable Unacceptable
8.9.15 CF_FILSCRL Command
Command “CF_FILSCRL_%1” [CR]
%1 “RST” - Reset Filter scroll counter
Detail Reset Filter scroll counter
Acceptable Acceptable
Response
Unacceptable Unacceptable
8.9.16 CF_TESTPAT Command
Command “CF_TESTPAT_%1” [CR]
%1
“COLOR” - Display Color bar
“GRAD1” - Display 16step(white→black)
“GRAD2” - Display 16step(white←black)
“GRAD3” - Display 16step(white↓black)
“GRAD4” - Display 16step(white↑black)
“WHITE” - Display all white
“BALCK” - Display all black
“CROSS” - Display Cross
“OFF” -Do not show test pattern display
“UP” - Switch forward
“DN” - Switch backward
Detail
Execute test pattern display.(Available only in the normal Power ON
status)
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.9.17 CF_FDEFAULT Command
Command “CF_FDEFAULT_%1” [CR]
%1 “RST”
Detail
Return the settings to Factory Default status (Valid only when in the
normal Power ON status)
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]