Command with Address Specification
LX900 RS232 Codes-Expanded Technical Reference Information 8-29
020-000034-01 Rev 1. (03/08)
9.11.3 CR_VMUTE Command
Command “CR_VMUTE” [CR]
Detail Get Video mute setting status
Acceptable “000_%1” [CR]
%1
“ON” - Video mute is set to ON (Shutter Close).
“OFF” - Video mute is set to OFF (Shutter Open).
Response
Unacceptable “?” [CR]
9.11.4 CR_FREEZE Command
Command “CR_FREEZE” [CR]
Detail Get Freeze setting status
Acceptable “000_%1” [CR]
%1
“ON” - Freeze is set to ON.
“OFF” - Freeze is set to OFF.
Response
Unacceptable “?” [CR]
9.11.5 CR_P-TIMER Command
Command “CR_P-TIMER” [CR]
Detail Get Presentation Timer operating status
Acceptable “000_%1” [CR]
%1
“ON” - Presentation Timer is ongoing.
“STOP” - Presentation Timer is paused.
“OFF” - Presentation Timer is not active.
Response
Unacceptable “?” [CR]