Command with Address Specification
LX900 RS232 Codes-Expanded Technical Reference Information 8-19
020-000034-01 Rev 1. (03/08)
8.7.8 CF_VPOS Command
Command “CF_VPOS_%1” [CR]
%1
“015” - +15
“014” - +14 : “001” - +1
“000” - ±0
“‐ 01” -‐ 1 : “‐ 14” -‐ 14
“‐ 15” -‐ 15
“UP” - Increment setting value of Vposition by 1 “
DN” - Decrement setting value of Vposition by 1
Detail
Set V Position (Available only in the normal Power ON status)
*When selected screen mode is a setting except Custom, return “101” [CR] and the command is
not executed.
* When input is no signal, return “101” [CR] and the command is not executed.
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.7.9 CF_HSCALE Command
Command “CF_HSCALE_%1” [CR]
%1
“035” - +35
“031” - +31 : “002” - +2
“001” - +1
“000” - ±0
“‐ 01” -‐ 1
“‐ 02” -‐ 2 : “‐ 31” -‐ 31
“‐ 32” -‐ 32
“UP” - Increment setting value of Hscale by 1
“DN” - Decrement setting value of Hscale by 1
Detail
Set Hscale (Available only in the normal Power ON status)
*When selected screen mode is a setting except Custom, return “101” [CR] and the command is
not executed.
*When input is no signal, return “101” [CR] and the command is not executed.
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]