Command with Address Specification
8-2 LX900 RS232 Codes-Expanded Technical Reference Information
020-000034-01 Rev 1. (03/08)
9.4.3 CR_COLOR Command
Command “CR_COLOR” [CR]
Detail Get user controlled value of Color
Acceptable “000_%1” [CR]
%1 “000” – “063”
Response
Unacceptable “Error Code” [CR] -When command is invalid in the given
condition (such as being selected input)
“?” [CR] - When unknown command is received
9.4.4 CR_TINT Command
Command “CR_TINT” CR]
Detail Get user controlled value of Tint
Acceptable “000_%1” [CR]
%1 “000” – “063”
Response
Unacceptable “Error Code” [CR] -When command is invalid in the given
condition (such as being selected input)
“?” [CR] - When unknown command is received
9.4.5 CR_APCTRL Command
Command “CR_APCTRL” [CR]
Detail Get setting status of Auto Picture Control
Acceptable “000_%1” [CR]
%1 “L1” - Operate Auto Picture Control with Level1
“L2” - Operate Auto Picture Control with Level2
“OFF” - Set Auto Picture Control OFF
Response
Unacceptable “?” [CR]
9.4.6 CR_COLTEMP Command
Command “CR_COLTEMP” [CR]
Detail Get Color Temperature setting status
Acceptable “000_%1” [CR]
%1 “000” ~“003” “BLANK” - OSD Menu is blank (Neither of
Xlow / Low / Mid / High)
Response
Unacceptable “?” [CR]