10-2 LX900 RS232 Codes-Expanded Technical Reference Information
020-000034-01 Rev 1. (03/08)
10.2.2 When the command pipelining is needed
When it needs command pipelining, the operation is the same as the remote control as below:
Sending-side system issues commands every 100ms 2) When receiving an applicable command, the
function is executed repeatedly for120ms.
When receiving the same command in a row within 120ms, the function is repeatedly
executed for another 120ms from the moment of the second command reception.
When there is no incoming command after 120ms, the execution of pipelining is stopped.
When the projector receives other command within 120ms, the execution of pipelining is stopped.
10.3 Status Read Command with Address
10.3.1 Format
The PC issues a command in the format as below:
“A” Address “CR” Command [CR]
Or
“A” Address “CR_ Command [CR]
Address: 3-digit number (“001” – “999”)
Command: string (Refer to Basic and Expand Serial Commands)
The only projectors that have the address matching with the one in the received data decode the command, and
it returns required data.
Required Data [CR]
Required Data: String (Refer to Basic Status Read Commands)
When the received data cannot be decoded, it returns “? “ [CR]
Zobrazit stránku 89