Command with Address Specification
LX900 RS232 Codes-Expanded Technical Reference Information 8-11
020-000034-01 Rev 1. (03/08)
9.7.2 CR_SOURCE Command
Command “CR_SOURCE” [CR]
Detail Get selected Source
Acceptable “000_%1” [CR]
%1
“DIGITAL” - DVI Input is selected
“ANALOG - ANALOG RGB is selected
“VIDEO” - Video Input is selected
“S-VIDEO” - S-VIDEO Input is selected
“YPBPR” - Y/Pb/Pr Input is selected
“SDI1” - DF-SDI1 Input is selected
“SDI2”- - DF-SDI2 Input is selected
“HDCP” - HDCP Input is selected
“SCART” - SCART Input is selected
“NOCARD” - There is no board inserted
Response
Unacceptable
“Error Code” [CR] - When command is invalid in the given condition (such as
being selected input)
“?” [CR] - When unknown command is received
Komentáře k této Příručce