Command with Address Specification
8-26 LX900 RS232 Codes-Expanded Technical Reference Information
020-000034-01 Rev 1. (03/08)
9.10.19 CR_FILH Command
Command “CR_FILH” [CR]
Detail Get Filter used time
Acceptable “000_%1” [CR]
%1 “00000 - 99999”
Response
Unacceptable “Error Code” [CR]
9.10.20 CR_FILCOND Command
Command “CR_FILCOND” [CR]
Detail Get status of filter clog
Acceptable “000_%1” [CR]
%1
“CLOG” = Filter is clogged
“WARN” = Filter is nearly clogged
“CLEAN” = Filter is not clogged
Response
Unacceptable “Error Code” [CR]
9.10.21 CR_FILREPL Command
Command “CR_FILREPL” [CR]
Detail Get status of Filter cleaning / replacement time
Acceptable “000_%1” [CR]
%1
“1Y”-Filter Exchange time is over value of Filter Message.
“1N”-Filter Exchange time is not over value of Filter
Message.
Response
Unacceptable “Error Code” [CR]
9.10.22 CR_FILTIMER Command
Command “CR_FILTIMER” [CR]
Detail Get time to display Filter cleaning / replacement warning on screen
Acceptable “000_%1” [CR]
%1
“0400” - Display massage by 400h used.
“0700” - Display massage by 700h used.
“1000” - Display massage by 1000h used.
“OFF” - Off(Warning display is not displayed)
Response
Unacceptable “Error Code” [CR]