Command with Address Specification
8-2 LX900 RS232 Codes-Expanded Technical Reference Information
020-000034-01 Rev 1. (03/08)
8.4 Image Command
8.4.1 CF_CONT Command
Command “CF_CONT_%1” [CR]
%1 “000-063”- Directly specify setting value of Contrast
“UP”- Increment setting value of Contrast by 1
“DN”- Decrement setting value of Contrast by 1
Detail Set user controlled value of Contrast. (Available only in the normal Power ON status) The value
set by this command is not stored in the projector. Therefore, when the power is turned to ALL
OFF status, the value returns to the original setting. (It is stored in Suspend mode.)
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.4.2 CF_ BRIGHT Command
Command “CF_BRIGHT_%1” [CR]
%1 “000-063” - Directly specify setting value of Brightness
“UP” - Increment setting value of Brightness by 1
“DN” - Decrement setting value of Brightness by 1
Detail Set user controlled value of Brightness. (Available only in the normal Power ON status) The
value set by this command is not stored in the projector’s memory. Therefore, when the power is
turned to ALL OFF status, the value returns to the original setting. (It is stored in Suspend mode.)
Acceptable “000” [CR] Response
Unacceptable “Error Code” [CR]
8.4.3 CF_COLOR Command
Command “CF_COLOR_%1” [CR]
%1 “000-063”- Directly specify setting value of Color
“UP”- Increment setting value of Color by 1
“DN”- Decrement setting value of Color by 1
Detail Set user controlled value of Color. (Available only in the normal Power ON status) The value set
by this command is not stored in the projector’s memory. Therefore, when the power is turned to
ALL OFF status, the value returns to the original setting. (It is stored in Suspend mode.)
Acceptable “000” [CR] Response
Unacceptable “Error Code” [CR]