Command with Address Specification
8-28 LX900 RS232 Codes-Expanded Technical Reference Information
020-000034-01 Rev 1. (03/08)
9.11 Other Status Read Commands
9.11.1 CR_STATUS Command
Command “CR_STATUS” [CR]
Detail
Get operating status of Projector Same as “CR0” in basic command
except error code follows it.
Acceptable “000_%1” [CR]
%1
“00” = Power ON
“80” = Standby
“40” = Countdown in process
“20” = Cooling Down in process
“10” = Power Failure
“28” = Cooling Down in process due to abnormal
temperature
“88” =Standby after Cooling Down due to abnormal
temperature
“02” = Invalid RS-232C Command
“24” = Power Save/Cooling Down in process
“04” = Power Save
“21” = Cooling Down in process after turned Off due to
lamp failure
“81”= Standby after Cooling Down due to lamp failure
“2C” = Cooling Down in process after Power Off due to
Shutter management
“8C” = Standby after Cooling Down due to Shutter
management
Response
Unacceptable “Error Code” [CR]
9.11.2 CR_SIGNAL Command
Command “CR_SIGNAL” [CR]
Detail Get status if there is any signal or not
Acceptable “000_%1” [CR]
%1
“ON” - There is signal
“OFF” - There is no signal
Response
Unacceptable “?” [CR]
Komentáře k této Příručce