Command with Address Specification
LX900 RS232 Codes-Expanded Technical Reference Information 8-17
020-000034-01 Rev 1. (03/08)
8.7.2 CF_DZCENT Command
Command “CF_DZCENT_%1” [CR]
%1 “CENT” - Cancel Digital Zoom (CENT: “CENTER”)
Detail
Cancel Digital Zoom mode. (Valid only when in the normal Power ON
status and Input for Computer is selected.)
Acceptable “000” [CR]
Response
Unacceptable “101” [CR] - When input is Video
8.7.3 CF_KEYSTONE Command
Command “CF_KEYSTONE _%1” [CR]
%1
“UP” - Correct Keystone distortion to reduce upper part of image
“FUP” - Correct Keystone distortion to reduce upper part
“DN” - Correct Keystone distortion to reduce lower part of image
“FDN” - Correct Keystone distortion to reduce lower part largely
“LEFT” - Correct Keystone distortion to reduce left part of image
“FLFT” - Correct Keystone distortion to reduce left part largely
“RIGHT” - Correct Keystone distortion to reduce right part of image
“FRGT” - Correct Keystone distortion to reduce right part largely
“RST” - Set Keystone OFF
Detail
Change level of Keystone distortion correction (Available only in the
normal Power ON status). When reached the limit of the correction level,
projector accepts the command but does not execute it. Receiving this
command immediately invokes the operation. When trying to set the value
beyond available range, error code “201” is returned and the operation is
not executed. Example 1: When the correction level of the right part has
reached its upper limit and then the command “RIGHT” is received
Example 2: When the upper part correction allows only another step, and
then the command “FUP” is received.
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.7.4 CF_KEYSTONEMODE Command
Command “CF_KYSTNMODE _%1” [CR]
%1
“STR” - Set Keystone store mode to Store
“RST” - Set Keystone store mode to Reset
Detail Set Keystone store mode (Available only in the normal Power ON status)
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]