Command with Address Specification
8-28 LX900 RS232 Codes-Expanded Technical Reference Information
020-000034-01 Rev 1. (03/08)
8.9.18 CF_KEYDIS Command
Command “CF_KEYDIS_%1” [CR]
%1
“NONE” - RC & KEY are valid
“RC” - RC is invalid
“KEY” - KEY is invalid
Detail
Set the limitation of RC/KEY use (Valid only when in the normal Power ON
status)
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.9.19 CF_SHUTRCPROT Command
Command “CF_SHUTRCPROT_%1” [CR]
%1
“ON” - Disable RC key from controlling Shutter (Protection On)
“OFF” - Enable RC key to control Shutter (Protection Off)
Detail
Set valid / invalid of RC use on Shutter control function (Valid only when in
the normal Power ON status)
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.9.20 CF_SHUTKEYPROT Command
Command “CF_SHUTKEYPROT_%1” [CR]
%1
“ON” - Disable key on the top panel from controlling Shutter (Protection
On) “OFF” - Enable key on the top panel to control Shutter (Protection Off)
Detail
Set valid / invalid use of key on the top panel on Shutter control function.
(Valid only when in the normal Power ON status)
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.9.21 CF_SHUTH Command
Command “CF_SHUTH_%1” [CR]
%1
“005”-“180”-Specify setting time directly
“UP” - Add 1 minute
“DN” -Decrease 1 minute
Detail
Set time of operating shutter management function. (Valid only when in the
normal Power ON status) The status set by this command is stored in
EEPROM and setting remains effective even after the power is turned to
ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]