Command with Address Specification
8-24 LX900 RS232 Codes-Expanded Technical Reference Information
020-000034-01 Rev 1. (03/08)
9.10.10 CR_P-MANETIME Command
Command “CR_P-MAETIME” [CR]
Detail Get setting time for starting Power Management function
Acceptable “000_%1” [CR]
%1 “001 – 030” - 1 to 30 minutes
Response
Unacceptable “?” [CR]
9.10.11 CR_FANSPEED Command
Command “CR_FANSPEED” [CR]
Detail Get currently selected Fan Control Speed
Acceptable “000_%1” [CR]
%1
“MAX” - Max speed of Fan Control is selected
“NOR” - Normal speed of Fan Control is selected
Response
Unacceptable “?” [CR]
9.10.12 CR_KEYDIS Command
Command “CR_KEYDIS” [CR]
Detail Get setting status of RC/KEY use limitation (valid or invalid)
Acceptable “000_%1” [CR]
%1
“NONE” - RC & KEY are valid
“RC” - RC is invalid “KEY” - KEY is invalid
Response
Unacceptable “?” [CR]
9.10.13 CR_SHUTRCPROT Command
Command “CR_SHUTRCPROT” [CR]
Detail Get status if Shutter can be controlled by R/C
Acceptable “000_%1” [CR]
%1
“ON” - Shutter is not controllable by R/C
“OFF” - Shutter is controllable by R/C
Response
Unacceptable “?” [CR]
9.10.14 CR_SHUTKEYPROT Command
Command “CR_SHUTKEYPROT” [CR]
Detail Get status if Shutter can be controlled by key on the top panel
Acceptable “000_%1” [CR]
%1
“ON” - Shutter is not controllable by key on the top panel
“OFF” - Shutter is controllable by key on the top panel
Response
Unacceptable “?” [CR]