Command with Address Specification
8-30 LX900 RS232 Codes-Expanded Technical Reference Information
020-000034-01 Rev 1. (03/08)
9.11.6 CR_TEMPWARN Command
Command “CR_TEMPWARN” [CR]
Detail
Get the information about the temperature inside the projector (close to the
abnormal or in the abnormal status/in the safe temperature level/abnormal
status is not detected).
It is possible to get the information about more than one sensor all at once
if it is applicable.
Acceptable “000_%1” [CR]
%1
“*_*” Sensor 1 data comes first, and then one space, after
that sensor 2 data is followed.
Each data is as below:
• “W”- in or close to the abnormal temp. (Warning
Temp.)
• “S”- in the safe level of temperature (Safe Temp.).
• “N”- the given sensor does not detect abnormal temp.
e.g. “S_W” [CR] indicates that the temperature
detected at Sensor 1 is in the safe level while Sensor
2 in the abnormal temperature.
Response
Unacceptable “?” [CR]