Command with Address Specification
LX900 RS232 Codes-Expanded Technical Reference Information 8-17
020-000034-01 Rev 1. (03/08)
9.7.16 CR_IDSLOT4 Command
Command “CR_IDSLOT4” [CR]
Detail
Get ID information on Slot 4. This command is to recognize the inserted
slot board and specify the valid Input source.
Acceptable “000_%1” [CR]
%1 The same as CR_IDSLOT1
Response
Unacceptable “?” [CR]
9.8 Screen Status Read Commands
9.8.1 CR_SCREEN Command
Command “CR_SCREEN” [CR]
Detail Get currently selected screen image size
Acceptable “000_%1” [CR]
%1
“NORMAL” - Normal mode
“WIDE” - Wide mode
“FULL” - Full mode
“TRUE” - True mode
“CUSTOM” - Custom mode
Response
Unacceptable
“Error Code” [CR] - When command is invalid in the given
condition (such as being selected input)
“?” [CR] - When unknown command is received
9.8.2 CR_KYSTNMODE Command
Command “CR_KYSTNMODE” [CR]
Detail Get setting status of Keystone Store Mode
Acceptable “000_%1” [CR]
%1
“STR” - Store mode is “Store”
“RST” - Store mode is “Reset”
Response
Unacceptable “?” [CR] - When unknown command is received
9.8.3 CR_CEIL Command
Command “CR_CEIL” [CR]
Detail Get setting status of Ceiling
Acceptable “000_%1” [CR]
%1
“ON” - Ceiling projection is enabled
“OFF” - Ceiling projection is disabled
Response
Unacceptable “Error Code” [CR]