Command with Address Specification
LX900 RS232 Codes-Expanded Technical Reference Information 8-31
020-000034-01 Rev 1. (03/08)
9.11.7 CR_TEMPFAIL Command
Command “CR_TEMPFAIL” [CR]
Detail
Get the temperature inside the projector when the abnormal status occurs. It is possible to get
the temperatures for more than one sensor all at once if it is applicable.
Acceptable “000_%1” [CR]
%1
e.g. “_31.5F”[CR] _ indicates a space.
When the temperature goes under 0, the first character is “-”, not a space, as in
“-05.5F”. With more than one temperature sensors installed, projector returns
the responses for each sensor in a row, e.g., “_31.5F_35.2S” [CR]
The first data indicates sensor 1 data, then one space, and sensor 2 data is
followed. Last character in each data indicates the sensor’s status.
In the abnormal temperature
- “F” In the safe level of temperature
- “S” Neither in or close to the abnormal temp.
- “N” The second example above indicates that the temperature detected by
sensor 1 is 31.5, which means in the abnormal temperature, and at sensor 2 is
32.5 degrees, which is in the safe temperature.
When the abnormal temperature status is not occurred the data should be
“_00.0S”. When the projector is reset, “_00.0S” is set.
Every time abnormal temperature status is detected, it renews the data and
returns it. It only returns the renewed data of the latest abnormal temperature
and the previous data is cleared.
Response
Unacceptable “?” [CR]
9.11.8 CR_SERIALNO Command
Command “CR_SERIALNO” [CR]
Detail
Get value of the serial number. (For Dealer)
Acceptable “000_%1” [CR]
%1 Eight digits of alphanumeric characters
Response
Unacceptable “?” [CR]
9.11.9 CR_SHUTCOND Command
Command “CR_SHUTCOND” [CR]
Detail Get setting status of Shutter
Acceptable “000_%1” [CR]
%1
“SAFE” - Shutter operation is normal.
“FAIL” - Shutter operation is abnormal.
Response
Unacceptable “?” [CR]