LX900 RS232 Codes-Expanded Technical Reference Information 8-21
020-000034-01 Rev 1. (03/08)
9.9.8 CR_LAMPH Command
Command “CR_LAMPH” [CR]
Detail Get Lamp running time (in hours) * return actual lamp running time
Acceptable “000_%1_%2_%3_%4” [CR]
%1_%2 %3_%4
Lamp 1 data comes first, and then one space, after that
lamp 2 data is followed.
%1 = lamp No.1
%2 = lamp No.2
%3 = lamp No.3
%4 = lamp
No.4 In the case of 2-lamp model, % 1 and % 2 are
only used (There are no %3 and %4)
e.g., “0410_0410_0410_0410” [CR] ▪▪▪▪ Lamp No.1
= 410 Hours Lamp No.2 = 410 Hours Lamp No.3 = 410
Hours Lamp No.4 = 410 Hours
Note: Each data shall be 4 digits.
“9999” is returned for 10000 hours or more.
Response
Unacceptable “Error Code” [CR]
9.10 Setting Status Read Commands
9.10.1 CR_BACKGND Command
Command “CR_BACKGND” [CR]
Detail Get setting status of Screen for no signal
Acceptable “000_%1” [CR]
%1
“BLUE” - Blue Back is selected
“USER” - User is selected
“BLACK” - Black Back is selected
Response
Unacceptable “Error Code” [CR]
9.10.2 CR_DISP Command
Command “CR_DISP” [CR]
Detail Get Display setting status
Acceptable “000_%1” [CR]
%1
“ON” - Display is set to ON.
“CNTDWNOFF” - Display is set to Count down OFF.
“OFF” - Display is set to OFF.
Response
Unacceptable “?” [CR]