Command with Address Specification
8-20 LX900 RS232 Codes-Expanded Technical Reference Information
020-000034-01 Rev 1. (03/08)
8.7.10 CF_HPOS Command
Command “CF_HPOS_%1” [CR]
%1
“015” - +15
“014” - +14 : “002” - +2
“001” - +1
“000” - ±0
“‐ 01” -‐ 1
“‐ 02” -‐ 2 : “‐ 14” -‐ 14
“‐ 15” -‐ 15
“UP” - Increment setting value of Hposition by 1
“DN” - Decrement setting value of Hposition by 1
Detail
Set H Position (Available only in the normal Power ON status)
*When selected screen mode is a setting except Custom, return “101” [CR]
and the command is not executed.
* When input is no signal, return “101” [CR] and the command is not
executed.
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.8 Lamp Commands
8.8.1 CF_LAMPH Command
Command “CF_LAMPH_%1” [CR]
%1 “RSTn” (n=1-2) - Reset lamp 1-2 running time
Detail
Reset running time of the lamp specified in “n”. (Valid only when it is in the
normal Power ON status.)
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.8.2 CF_LAMPMODE Command
Command “CF_LAMPMODE_%1” [CR]
%1
“FULL” - Set lamp mode to 2-lamp (FULL)
“HALF” - Set lamp mode to 1-lamp (HALF)
Detail
Select Lamp mode. (Valid only when in the normal Power ON status.) The
value set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status. On Half mode, one
lamp with a fewer used-time light automatically.
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]