Command with Address Specification
8-26 LX900 RS232 Codes-Expanded Technical Reference Information
020-000034-01 Rev 1. (03/08)
8.9.11 CF_PJPINCODE Command
Command “CF_PJPINCODE_%1” [CR]
%1 “0000 – 9999” - Directly specify PJ PIN code
Detail
Enter PIN code to cancel PIN code lock (Available only in the normal
Power ON status) PIN code can not be changed. (Only PIN code lock is
canceled.) *When PIN code Lock is enabled:
PIN code is matched - Command is valid (Acceptable)
PIN code is mismatched - Command is invalid (Error code “102”)
PIN code is beyond %1 available range - Command is invalid (Error
code”?”) When PIN code lock is canceled:
PIN code is within %1 range - Command is valid (Acceptable)
PIN code is out of %1 range - Command is invalid (Error code is 102) This
command is only valid when “PJ PIN code” dialog is displayed to enter PIN
code after Power is ON and Countdown is completed. When PIN code lock
is set to “On1”, it needs to send this command every time the projector is
turned on.
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.9.12 CF_FILH Command
Command “CF_FILH_%1” [CR]
%1 “RST” - Reset Filter used time
Detail Reset used time for filter of projector
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.9.13 CF_FILTIMER Command
Command “CF_FILTIMER_%1” [CR]
%1
“0400” - Set 400 hours
“0700” - Set 700 hours
“1000” - Set 1000 hours
“OFF” - Set Off(Do not warning display)
Detail Set time to display Filter cleaning / replacement warning on screen
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]