Command with Address Specification
8-18 LX900 RS232 Codes-Expanded Technical Reference Information
020-000034-01 Rev 1. (03/08)
8.7.5 CF_CEIL Command
Command “CF_CEIL_%1” [CR]
%1
“ON” - Set Ceiling to ON
“OFF” - Set Ceiling to OFF
Detail
Set/Cancel Ceiling. (Valid only when in the normal Power ON status.) When Ceiling is set to ON,
image is left/right as well as top/bottom reversed. The status set by this command is stored in
EEPROM and the setting remains effective after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.7.6 CF_REAR Command
Command “CF_REAR_%1” [CR]
%1
“ON” - Set Rear to ON
“OFF” - Set Rear to OFF
Detail
Set/Cancel Rear. (Valid only when in the normal Power ON status.) When Rear is set to ON,
image is left/right reversed. The status set by this command is stored in EEPROM and the setting
remains effective after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.7.7 CF_VSCALE Command
Command “CF_VSCALE_%1” [CR]
%1
“035” - +35
“031” - +31
“001” - +1
“000” - ±0
01” - 1
31” - 31
32” - 32
“UP” - Increment setting value of Vscale by 1
“DN” - Decrement setting value of Vscale by 1
Detail
Set Vscale (Available only in the normal Power ON status) *When selected screen mode is a
setting except Custom, return “101” [CR] and the command is not executed. * When input is no
signal, return “101” [CR] and the command is not executed.
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]